Water quality online monitoring systems are deployed at surface water sections, drinking water sources, wastewater treatment plant discharge outlets and industrial park pipelines that require continuous automatic monitoring. The cabinet-type analyzers automatically sample, digest, measure and report COD, ammonia nitrogen, total phosphorus, total nitrogen, pH, dissolved oxygen and turbidity, uploading data via 4G / 5G or Ethernet to environmental platforms for real-time alarm and total-volume control.
The HQT-W series supports single and multi-parameter configurations with sampling pre-treatment, auto-cleaning, quality control, temperature control and surge protection built into the cabinet β suitable for riverside, pump station and park outdoor conditions, with OEM / ODM customization.
COD, ammonia nitrogen (NH3-N), total phosphorus (TP), total nitrogen (TN), pH, dissolved oxygen (DO), turbidity, conductivity β combinable.
Dichromate (COD), salicylate/Nessler (ammonia), ammonium molybdate (TP), persulfate digestion (TN), electrode (pH/DO).
Continuous automatic measurement, 30-120 min configurable, manual / remote on-demand.
HJ212-2017 protocol, 4G / 5G / Ethernet to provincial, municipal & park platforms.
IP54 cabinet with temperature control & surge protection, -10β ~ +45β outdoor.
AC 220V primary, optional solar + battery backup.
HQT-W series single / multi-parameter, ranges customizable
| Model | Parameter | Method | Typical Range |
|---|---|---|---|
| HQT-W-COD | COD | Dichromate | 0-200 / 0-5000 mg/L |
| HQT-W-NH3N | Ammonia Nitrogen | Salicylate | 0-10 / 0-100 mg/L |
| HQT-W-TP | Total Phosphorus | Ammonium molybdate | 0-2 / 0-50 mg/L |
| HQT-W-TN | Total Nitrogen | Persulfate digestion | 0-20 / 0-100 mg/L |
| HQT-W-pH | pH | Glass electrode | 0-14 pH |
| HQT-W-DO | Dissolved Oxygen | Fluorescence | 0-20 mg/L |
| HQT-W-SS | Suspended Solids / Turbidity | Light scattering | 0-1000 NTU |
Provide parameters, ranges, discharge standards and point count.
Get a Quote